Design Features
Pivoting radial or taintor gate for water level control in channels and spillways and for regulation and discharge of bottom outlets in dams and reservoirs
Pivoting taintor / radial gate for installation in channels and dam spillways either as a water / wastewater flow control or as a dam outflow regulating and discharge system.
Industries
WTP, WWTP, Waterworks
Materials
Gate : S275JR, Arms: S275JR, Hydraulic Cylinder: Steal with shaft in ASI 420, Bearing shaft: AISI 431
Pressure and Temperature
ORBINOX “Taintor” radial gates are designed for:
a) Spillway gates: supporting water loads equal to the maximum gate height plus the specified overspill in each case.
Consult our technicians about special overspills and/or higher water loads.
b) Bottom outlet gates: water loads of up to 100 mwc.
Size
as required size of opening
Connection
Spilway and Bottom outlet